Tube-tech LCA 2B Dual Channel Tube VCA Compressor Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Audio-Zubehör Tube-tech LCA 2B Dual Channel Tube VCA Compressor herunter. Tube Tech LCA 2B Dual Channel Tube VCA Compressor User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
LYDKRAFT ApS
Mose Allé 20, DK-2610 Rødovre
Denmark
1
UsersManual
TUBE-TECH LCA 2B
compre ssor and limite r
DESCRIPTION:
The TUBE-TECH LCA 2B is a two-channel unit with an independent compressor and
limiter per channel. The unit is all tubebase d (except for the power supply and si-
dechain circuit). Output gaincontrol is placed between the VCA an d outpu t stage. The
VCA (1 dual triode) is pl aced between the i nput transformer and the output stage (2
dual triodes). The audio signal is pi cked up after the VCA and fed to the sidechain
circuit. The control signal from t he compressor and from the limite r is combi ned and
sent to the link switch and to th e control amp, which feeds the VCA. The bi-directional
link busses a re accessible at two 1/4" stereo jack sockets on the rear panel. The
channels can be linked toge ther for stereo appli cations and a lso linked to other LCA
2B's via the two link busses and a standard stereo jack/jack cord.
The compressor has six att ack/release presets as well as manual control.Thelimiter
attack/release is fixed an d equipped wi th an on/off switch.
The LED display is fed from th e control amp. T h e limiter LED is fed fr o m the limiter
buffer.
The audio path is fully symmetrical from input to output .
Input and ou tput have fully floating transformers.
All DC voltages are stabilised, except the anode voltag e for the output stage, which is
only filtered.
COMPRESSOR INTERCONNECTION:
The sidechain sockets for interconn ection of seve ral compressors are located on the
rear panel.
A switch (LINK 1, LINK 2) on the front sele cts which compressors are interconnect ed,
and on which bu s they are connected. If you select LINK 1 on both channels, they will
perform exact the same ga inreduction.
Having several connected co mpressors in a rack, you can sele ct which compressors
you will have working together.
By selecting e.g. LCA 2B no 1, ch . 1 on link 1, LCA 2B no 2, ch. 2 on link 1 and LCA
2B no 3, ch. 1 on link 1, they are now interconnected and all t hree will perform the
exact same compression.
The interconnection implies, that the unit, which performs the most compression, is
controlling the others.
To choose which one you want to control, select the a t tack/release time, the threshold
and the ratio on that unit, and turn the threshold fully counter clockwise on the
reminding compressors.
It is of co urse possible to have all the interconnected comp ressors control each other
simultaneously.
(150205)
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - TUBE-TECH LCA 2B

LYDKRAFT ApSMose Allé 20, DK-2610 RødovreDenmark1UsersManualTUBE-TECH LCA 2Bcompre ssor and limite rDESCRIPTION:The TUBE-TECH LCA 2B is a two-channel

Seite 2 - (940530)

LYDKRAFT ApSMose Allé 20, DK-2610 RødovreDenmark2CONTROLS:GAIN:Thegaincontrol is used to "adjust" for the gain loss, which takesplace when t

Seite 3

LYDKRAFT ApSMose Allé 20, DK-2610 RødovreDenmark3ATTACK/RELEASE SELECT:This switch selects how the compressor reacts to an increase(attack) or decreas

Seite 4

LYDKRAFT ApSMose Allé 20, DK-2610 RødovreDenmark4ADJUSTMENT PROCEDURE:CAUTION:Before making any adjustment let the unit heat-up at least 30 min.Always

Seite 5

LYDKRAFT ApSMose Allé 20, DK-2610 RødovreDenmark5ADJUSTMENT OF DISPLAY:1) Turn theTHRESHOLD-control for the compressor and limite r fullycounter-clock

Seite 6 - (941010)

LYDKRAFT ApSMose Allé 20, DK-2610 RødovreDenmark6ADJUSTMENT OF BALANCE IN THE VCA TUBE (V1, V101):As a quick check of the balance of the VCA tube , ad

Seite 7

LYDKRAFT ApSMose Allé 20, DK-2610 RødovreDenmark7SPECIFICATIONS FOR LCA 2BInput impedance:>2kOutput impedance:<60Dist orti on(THD+n @ 40 Hz):0

Seite 8

LYDKRAFT ApSMose Allé 20, DK-2610 RødovreDenmark8SERVICE HINTS:(940530)SYMPTOM CAUSE ACTIONNoise Unbalance in VCA tube Adjust balanceNoise Noisy VCA t

Kommentare zu diesen Handbüchern